Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Custom Calibrations

Creating a custom calibration (optional)

Media owners can optionally calibrate their Flow installation, to define their own value for CC, which can be done either remotely, or on-site:

Creating a calibration in OOH Studio

The default calibration can (optionally) be fine-tuned in the OOH Studio Flow Page, by clicking "Add Calibration" at the top of the calibrations table.

  • Enter a known value of aggregate ad impressions retrieved from another data source, for a specific face/player. This could be data you are already trading against, footfall data you have received from a landlord, or data from another measurement service, etc.

  • Select the face/player from the list of inventory that this sample is associated with.

  • Enter the time period that this known data value covers.

Calibrations made in OOH studio must use a minimum of 15 minute time intervals.

  • Click Submit

  • Flow will then find, and compare, the wireless measurement data for the same time period and a new calibration will appear in the ready to review section, once the corresponding wireless data is available in the cloud.

Creating a calibration on-site (Mobile App)

The OOH Studio mobile app is the most accurate way to create a custom calibration, and will allow any length of calibration window, down to a single ad play. It is recommended that the minimum on-site calibration is 2 minutes or more.

The app synchronises data for people counted on site with the corresponding wireless measurement data to create a highly accurate calibration profile, directly referencing inputted audience obervations against correspoding wireless measurement data.

The mobile application automatically detects in-range Catch Media gateway devices, and creates a timeline of measurement inputs, synchronised with each ad play.

  • Observe the flow of people passing the field of visibility of the OOH face.

  • Your device will vibrate every time a new ad play begins, so that there is no need to look at the mobile app while counting.

  • Use the large + and - buttons to count the number of people in front of the screen between vibrations.

  • Each time the device vibrates, start the count again, counting the same person again, if applicable.

  • Press the ✅ button in the top right after at least 2 minutes of counting in this way to complete the session.

  • A summary page is shown, where you can review, amend, submit or delete the session.

  • Submitted sessions appear in the ready to review section of OOH Studio in the web browser.

Reviewing a calibration

Whether a calibration was created remotely or on-site, it will appear in the "Ready to Review" section

Click "Review" on the calibration you wish to review, from the table of calibrations.

  • Flow will then show the quality of the wireless measurement data and ad playback coverage for the given sample period, the categorised number of MAC detections over the ad plays in that period, and a new calculated value for CC , and how it was derived from raw data.

  • You may choose to include ignored categories, though this is strongly advised against in most cases.

  • You can then preview the applied calibration, by clicking "Preview Calibration"

Previewing calibration

The standard flow impression charts will then be displayed, allowing you to view historical and live data against the newly created calibration value - so that the impact of the new calibration can be truly understood.

Full details of the usage of this page can be found in the Impression Charts section

If you are happy with the recalculated impression values, you may apply it to live data going forward using the "Apply to locations" + button.

Changing the calibration value will not affect historical campaign or face performance metrics/charts, and will only apply from the point of application going forwards.

Last updated